The MSLAB63 is a fully automatic 3-part hematology analyzer designed for clinical and laboratory use to perform fast and accurate complete blood counts (CBC) with a 3-part WBC differential and a total of 21 assay parameters.
The analyzer processes up to 60 samples per hour, providing high throughput suitable for busy clinics and diagnostic labs.
It reports 21 parameters including WBC, LYM#/% , NEU#/% , MXD#/% , RBC, HGB, HCT, MCV, RDW-SD, RDW-CV, MCH, MCHC, PLT, PCT, PDW, P-LCR, P-LCC and provides WBC, RBC and PLT histograms.
The analyzer requires as little as 6 µL of whole blood per test, minimizing invasiveness and sample consumption.
It uses electro-impedance counting combined with photometric analysis to obtain cell counts and hemoglobin measurements.
Results are shown on a 10.4-inch resistive touchscreen and can be stored internally with a capacity of up to 10,000 test results for review and retrieval.
The unit supports AC 110 V 60 Hz or AC 220 V 50 Hz power supplies for global compatibility—confirm local voltage and plug type with your supplier.
The analyzer dimensions are approximately 328 mm × 425 mm × 446 mm and it weighs about 16.0 kg, making it compact and portable for lab bench use.
Yes. It is designed for fully automatic operation with a user-friendly touchscreen interface to reduce manual steps and minimize operator error.
The analyzer supports routine QC procedures and calibration as recommended by the manufacturer. Follow supplied QC/JQC procedures and run controls per your laboratory's regulatory requirements.
Routine maintenance typically includes daily cleaning cycles, reagent and control materials, waste removal, and periodic replacement of reagents and consumables. Refer to the user manual for specific schedules and part numbers.
The analyzer stores test results internally (up to 10,000). For export and LIS integration capabilities, check the technical manual or contact your supplier—specific communication interfaces may vary by configuration.
The MSLAB63 is intended for clinical laboratories, hospitals, and diagnostic centers. Install on a stable bench in a clean, temperature-controlled environment following the manufacturer's site requirements.
Frequency depends on laboratory policy and local regulations; many labs run QC daily and after reagent changes or maintenance. Always follow the manufacturer's recommendations and your accreditation requirements.
Contact the authorized distributor or manufacturer for technical support, spare parts and warranty terms. They can provide service contracts, user training, and original consumables.