B21, China Town Mall, Midrand
Welcome to Afrimart OnlineWrap new offers/gift every single day on Weekends.New Coupon Code: Fast024
Something you love is now on sale! Buy Now !
Titration Method Cement Chloride Ion Tester Potentiometric Titration of Cement Chloride ion analyzer

0 Customer Reviews

  • Shipping Timeframes: All orders are processed within 2-5 business days (excluding weekends and holidays). After your order has been processed, the estimated delivery time is before 04 Feb, 2026, depending on customs, Please note that due to high demand, some items may experience longer shipping times, which will be communicated at order confirmation email.
  • Order Processing Time: Please allow 2-5 business days for us to process your order before it is shipped . Orders placed after 16:00 on Fridays, or during weekends and public holidays, will begin processing on the next business day. Processing times may be extended during peak seasons or sales events.
  • Manufacturing Time: Some products needs manufacturing time, the manufacturing process will take approximately 10-30 business days depending on the product. This timeframe may vary depending on the complexity of the product and current demand. but this will be communicated with you during order confirmation.
  • Returns and Exchanges: We offer a 30-day return policy for most items. If you are not completely satisfied with your purchase, you may return it within 30 days of receipt for a refund or exchange. Items must be unused, in their original packaging, and accompanied by proof of purchase. Return shipping costs are the responsibility of the customer, unless the item was damaged or defective upon arrival.
1. What is the primary function of the Titration Method Cement Chloride Ion Tester?

The primary function of the Titration Method Cement Chloride Ion Tester is to accurately measure the chloride ion levels in cement using the potentiometric titration method.

2. How does the potentiometric titration method work?

The potentiometric titration method works by measuring the voltage change in a solution as a titrant is added, allowing for precise determination of ion concentrations.

3. What industries can benefit from using this analyzer?

Industries such as construction, manufacturing, and research can benefit from using this analyzer for quality control and testing of cement chloride ion levels.

4. Is the tester user-friendly?

Yes, the tester features a 7-inch color touch screen that provides a user-friendly and intuitive interface for easy operation.

5. Can the testing parameters be adjusted?

Yes, all reagent parameters can be modified for a wider range of usage, allowing for flexibility in testing.

6. What is the maximum measurement range of the analyzer?

The measurement range of the Titration Method Cement Chloride Ion Tester is from 0 to 1950.0 mV.

7. How is the accuracy of the measurements ensured?

The analyzer features high precision stepper motor control and allows for calibration to minimize system errors, ensuring accurate results.

8. What is the burette capacity tolerance?

The burette capacity tolerance is ± 0.05 mL, which helps ensure precise titration.

9. Does the analyzer support data storage?

Yes, it can save up to 200 sets of historical data and supports USB export for easy data management.

10. How long does it take to refill the burette?

The burette refill speed is approximately 30 seconds when the burette is full.

11. What types of beakers are supported by the analyzer?

The analyzer supports 150 mL and 200 mL beaker types for testing.

12. What maintenance features does the tester have?

The tester includes an automatic cleaning function for easy maintenance, ensuring consistent performance.

13. What is the basic error margin of the measurements?

The basic error margin is ± 0.05% F.S, which indicates high reliability in measurement accuracy.

14. Is the device suitable for research and development purposes?

Yes, the analyzer is suitable for research and development of new cement products due to its precise measurement capabilities.

15. What is the power supply requirement for this analyzer?

The analyzer requires a power supply voltage of 220V ± 10%.

0

0 Overall Rating
  • 5
    0%
    0
  • 4
    0%
    0
  • 3
    0%
    0
  • 2
    0%
    0
  • 1
    0%
    0

Review this product

For you to write a review, you need to login first

Login

Latest Order Arrivals

Discover our latest orders

12 Heads Embroidery Machine
12 Heads Embroidery Machine
Dewatering Pump Machine
Dewatering Pump Machine
Order Collection
Order Collection
Portable Water Drilling Rig
Portable Water Drilling Rig
Order Usefully Collected
Order Usefully Collected
Batch of Orders
Batch of Orders
Agriculture Processing Machines
Agriculture Processing Machines
Meat Grinder Machine
Meat Grinder Machine
Water Pump Equipment
Water Pump Equipment
Packaging Machine and accessories
Packaging Machine and accessories
Fabrics Manufacturing Equipment
Fabrics Manufacturing Equipment
Mining Equipments
Mining Equipments
Food Processing Machine
Food Processing Machine
Batch of Orders
Batch of Orders
Batch of Orders
Batch of Orders
Latest Orders Labelled
Latest Orders Labelled
wheel alignment machines
wheel alignment machines
new arrivals
new arrivals
Pre Orders Offloading
Pre Orders Offloading
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals

Related Products

Recently Viewed Products